Hi,guys!
I want use EXT16 tools to extract parasitic.
When I create qrtTechFile use ICT file,I find the Techgen -compilation cmd has a option -cap_correction can subtracts calculated plate-to-plate capacitance from the parasitic capacitance between the two nets of a canonical capacitor,but it does not work on finger CAP(like mimcap) devices in RC extraction mode.
Now, I want subtract the finger CAP too in RC extraction mode,how can i do?
Any help are best !
Best regards!
Gong