EDI101 'accu.vh' not found.

$
0
0

 Hi,

 I am only administrator, not a designer. I finished installing EDI101 in order for community to use encounter. They have a .tcl file that they used with previous version of encounter on Sparc. Mst probably sparc platform has nothing to do with error. Here is the message I receive.

 

 encounter -init encounter.tcl
Checking out Encounter license ...
Encounter_Digital_Impl_Sys_XL 10.1 license checkout succeeded.
You can run 2 CPU jobs with the base license that is currently checked out.
If required, use the setMultiCpuUsage command to enable multi-CPU processing.
This Encounter release has been compiled with OA version 22.04-p013.

*******************************************************************
*   Copyright (c)  Cadence Design Systems, Inc.  1996 - 2011.     *
*                     All rights reserved.                        *
*                                                                 *
*                                                                 *
*                                                                 *
* This program contains confidential and trade secret information *
* of Cadence Design Systems, Inc. and is protected by copyright   *
* law and international treaties.  Any reproduction, use,         *
* distribution or disclosure of this program or any portion of it,*
* or any attempt to obtain a human-readable version of this       *
* program, without the express, prior written consent of          *
* Cadence Design Systems, Inc., is strictly prohibited.           *
*                                                                 *
*                 Cadence Design Systems, Inc.                    *
*                    2655 Seely Avenue                            *
*                   San Jose, CA 95134,  USA                      *
*                                                                 *
*                                                                 *
*******************************************************************

@(#)CDS: Encounter v10.13-s292_1 (32bit) 08/15/2012 15:12 (Linux 2.6)
@(#)CDS: NanoRoute v10.13-s033 NR120726-2234/10_10_USR3-UB (database version 2.30, 132.4.1) {superthreading v1.16}
@(#)CDS: CeltIC v10.13-s064_1 (32bit) 06/28/2012 06:48:30 (Linux 2.6.9-89.0.19.ELsmp)
@(#)CDS: AAE 10.13-s008 (32bit) 08/15/2012 (Linux 2.6.9-89.0.19.ELsmp)
@(#)CDS: CTE 10.13-s020_1 (32bit) Aug 15 2012 06:35:34 (Linux 2.6.9-89.0.19.ELsmp)
@(#)CDS: CPE v10.13-s240
--- Starting "Encounter v10.13-s292_1" on Tue Oct 30 16:50:50 2012 (mem=46.1M) ---
--- Running on hostname.domainname.com (x86_64 w/Linux 2.6.18-308.el5) ---
This version was compiled on Wed Aug 15 15:12:02 PDT 2012.
Set DBUPerIGU to 1000.
Set net toggle Scale Factor to 1.00
Set Shrink Factor to 1.00000
Sourcing tcl/tk file "encounter.tcl" ...
Reading config file - ./encounter.conf
**WARN: (ENCEXT-1085):    Option 'rda_Input(ui_res_scale)' used in configuration file './encounter.conf' is obsolete. The name will be converted into new format automatically if design is saved and then restored. Alternatively, update the configuration file to use names 'rda_Input(ui_preRoute_res)' and/or 'rda_Input(ui_postRoute_res)' for resistance scale factors to be used at preRoute/postRoute stages of the design . The obsolete name works in this release. But to avoid this warning and to ensure compatibility with future releases, update this option name.
**ERROR: (ENCSYT-16038):    'accu.vh' not found.

Loading Lef file /apps/FreePDK45/osu_soc/lib/files/gscl45nm.lef...
**WARN: (ENCLF-155):    ViaRule only supports routing/cut layer, but poly layer found for viaRule 'M1_POLY',
Set DBUPerIGU to M2 pitch 380.

Power Planner/ViaGen version 8.1.46 promoted on 02/17/2009.
viaInitial starts at Tue Oct 30 16:50:52 2012
viaInitial ends at Tue Oct 30 16:50:52 2012
**ERROR: (ENCSYT-16038):    'accu.vh' not found.
Reading netlist ...
Backslashed names will retain backslash and a trailing blank character.

*** Memory Usage v#1 (Current mem = 208.230M, initial mem = 46.070M) ***
*** End netlist parsing (cpu=0:00:00.0, real=0:00:00.0, mem=208.2M) ***
**ERROR: (ENCSYC-300):    Cell accu not found.
**ERROR: (ENCVL-904):    Can't set top cell to "accu" because it doesn't exist.  Exiting Encounter!

*** Memory Usage v#1 (Current mem = 208.645M, initial mem = 46.070M) ***
--- Ending "Encounter" (totcpu=0:00:03.2, real=0:00:09.0, mem=208.6M)

 

Is this an installation problem/media problem or .tcl/.conf needs modification ? Thanks.